Fire Rated Gypsum Board Type X Ratings Standards and Specification Guide

Fire Rated Gypsum Board Type X Ratings Standards and Specification Guide

Brand Name: SUNHOUSE
MOQ: 500 pcs
Supply Ability: 3000000 Meter/Meters per Month
Detail Information
Place of Origin:
Guangdong
Warranty:
1 Year
After-sale Service:
Online Technical Support, Onsite Inspection, Free Spare Parts
Application:
Indoor, Hotel, Villa, Apartment, Office Building
Design Style:
Modern
Feature:
Fire Resistant Plasterboard
Material:
Pure Natural Gypsum
Color:
Red
Usage:
Internal Wall Partition
Edge:
Square Or Tapered
Thickness:
12.5mm
Regular Size:
1220mm*2440mm
Packaging Details:
Our timber packed in pallet or in bulk/Loose packing(pallet is covered with package board and PVC tapes)
Supply Ability:
3000000 Meter/Meters per Month
Highlight:

Fire rated gypsum board type X

,

Fire resistant plasterboard specifications

,

Gypsum board fire rating standards

Product Description

Fire Rated Gypsum Board Type X: Ratings, Standards and Specification Guide

Fire rated gypsum board Type X is a gypsum panel formulated with glass fibres and other additives so that it performs substantially better than standard board when exposed to fire. It is the base component of rated partitions, ceilings and shaft walls.

What "Type X" Actually Means

Type X is a defined designation, not a marketing term. Under ASTM C1396, a Type X gypsum board must achieve a fire resistance rating of not less than one hour when tested in a specified assembly to ASTM E119. Under EN 520, the comparable designation is Type F, typically used in systems classified to EN 13501-1. GB/T 9775 defines the equivalent grades for the Chinese market.

The rating belongs to the assembly, not the panel. Board, studs, insulation, fastening pattern and joint treatment all contribute. Any supplier claiming a bare panel is "2-hour fire rated" is misstating the standard.

Typical Availability

Thickness Common Use Rating Potential
12.5 mm Partitions, ceilings 30–60 min in tested assemblies
15.9 mm (5/8") Standard Type X panel 1 hour typical
15.9 mm doubled High-rise shafts, stairwells Up to 2 hours in tested designs
19 / 25 mm Shaftwall, industrial 2 hours and above

Specification Checklist

  • Declared standard and type — ASTM C1396 Type X, EN 520 Type F, GB/T 9775
  • Thickness and number of layers per the tested design
  • Stud type, gauge and spacing
  • Cavity insulation type and density
  • Joint treatment and head-of-wall detailing

What We See on Project Sites

We have supplied fire rated board into high-rise cores, hospitals, data centres and industrial plants, and the same question comes up from buyers every time: is Type X the same from every mill? It is not. Fibre content, core density and paper adhesion vary, and those variables determine whether a wall passes inspection. Common defects we record are joints aligned across layers, under-specified fasteners and unsealed perimeter gaps — installation issues, not board issues, but they void the rating just the same.

Verification and Documentation

Panels are produced to ASTM C1396 Type X, EN 520 Type F or GB/T 9775, from factories operating under ISO 9001. Fire test reports from accredited laboratories are available for the assemblies we support, together with material data sheets and installation manuals. Where a proprietary tested design applies, its instructions govern — and if our panel is not listed in the assembly your project requires, we say so before the order rather than after delivery.

Frequently Asked Questions

Is Type X board fireproof?

No building material is fireproof. Type X board delays fire spread and structural failure for a defined period, measured in a tested assembly.

Can Type X be used in wet areas?

Yes. Boards combining a moisture resistant core with a fire rated core are available.

Does thicker board always mean a higher rating?

Not automatically. The rating depends on the complete assembly tested to ASTM E119.

Can I substitute another brand of the same thickness?

Only if that panel is listed in the same tested assembly. Otherwise the rating is void.

Send your wall types and required fire ratings; we will recommend the panel and assembly configuration with supporting test documentation.